{"id":2728,"date":"2026-10-18T17:37:54","date_gmt":"2026-10-18T13:37:54","guid":{"rendered":"https:\/\/abm.byferas.com\/product\/18-port-gigabit-poe-network-switch-with-2-sfp\/"},"modified":"2026-10-24T17:57:29","modified_gmt":"2026-10-24T13:57:29","slug":"18-port-gigabit-poe-network-switch-with-2-sfp","status":"publish","type":"product","link":"https:\/\/abmmaster.com\/ar\/product\/18-port-gigabit-poe-network-switch-with-2-sfp\/","title":{"rendered":"\u0633\u0648\u064a\u062a\u0634 \u0634\u0628\u0643\u0629 \u062c\u064a\u062c\u0627\u0628\u062a PoE \u0628\u0640 18 \u0645\u0646\u0641\u0630 \u0645\u0639 \u0645\u0646\u0641\u0630\u064a SFP"},"content":{"rendered":"<div class=\"abm-banners\"><img decoding=\"async\" class=\"abm-banner-d\" src=\"https:\/\/abmmaster.com\/wp-content\/uploads\/2026\/10\/abm-pln-1116gb-sfp-18-port-gigabit-poe-switch-poe-network-banner-desktop-3.jpg\" alt=\"18-Port Gigabit PoE Network Switch with 2 SFP\" loading=\"lazy\"><img decoding=\"async\" class=\"abm-banner-m\" src=\"https:\/\/abmmaster.com\/wp-content\/uploads\/2026\/10\/abm-pln-1116gb-sfp-18-port-gigabit-poe-switch-poe-network-banner-mobile-3.jpg\" alt=\"18-Port Gigabit PoE Network Switch with 2 SFP\" loading=\"lazy\"><\/div>\n<h3>\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a<\/h3>\n<table class=\"abm-specs\">\n<tbody>\n<tr>\n<th>Model<\/th>\n<td>PLN-1116GB-SFP<\/td>\n<\/tr>\n<tr>\n<th>Fixed Port<\/th>\n<td>2*10\/100\/1000Base-T uplink RJ45 ports (Data) 16*10\/100\/1000Base-T PoE ports (Data \/Power) 2*1000Base-X uplink SFP fiber ports (Data)<\/td>\n<\/tr>\n<tr>\n<th>Ethernet Port<\/th>\n<td>Port 1-16 can support 10\/100\/1000Base-T auto-sensing, full\/half duplex MDI\/MDI-X self-adaption<\/td>\n<\/tr>\n<tr>\n<th>Twisted Pair Transmission<\/th>\n<td>100BASE-TX: Cat5 or later UTP (\u2264100 meters) 1000BASE-T: Cat5e or later UTP (\u2264100 meters) 10BASE-T: Cat3, 4, 5 UTP (\u2264100 meters)<\/td>\n<\/tr>\n<tr>\n<th>Optical Fiber Port<\/th>\n<td>Gigabit optical fiber interface, default no include optical module (optional single-mode\/multi-mode, single fiber\/dual fiber optical module. LC)<\/td>\n<\/tr>\n<tr>\n<th>Optical Cable\/ Distance<\/th>\n<td>Multi-mode: 850nm\/0-550m, Single-mode: 1310nm\/0-40km, 1550nm\/0-120km<\/td>\n<\/tr>\n<tr>\n<th>Network Protocol<\/th>\n<td>IEEE 802.3 10BASE-T, IEEE 802.3i 10Base-T, IEEE 802.3u 100Base-TX, IEEE 802.3ab 1000Base-T, IEEE 802.3z 1000Base-X, IEEE 802.3x<\/td>\n<\/tr>\n<tr>\n<th>Forwarding Mode<\/th>\n<td>Store and Forward (Full Wire Speed)<\/td>\n<\/tr>\n<tr>\n<th>Switching Capacity<\/th>\n<td>56Gbps (non-blocking)<\/td>\n<\/tr>\n<tr>\n<th>Forwarding Rate @64byte<\/th>\n<td>29.76Mpps<\/td>\n<\/tr>\n<tr>\n<th>MAC<\/th>\n<td>8K<\/td>\n<\/tr>\n<tr>\n<th>Buffer Memory<\/th>\n<td>4M<\/td>\n<\/tr>\n<tr>\n<th>Jumbo Frame<\/th>\n<td>9.6K<\/td>\n<\/tr>\n<tr>\n<th>LED Indicator<\/th>\n<td>Power: PWR (Green), Network: Link, Link\/Act (Yellow), PoE: PoE (Green), Fiber port: L\/A (Green)<\/td>\n<\/tr>\n<tr>\n<th>Reset Switch<\/th>\n<td>Yes, One-button factory reset<\/td>\n<\/tr>\n<tr>\n<th>PoE Port<\/th>\n<td>Port 1-16<\/td>\n<\/tr>\n<tr>\n<th>Power Supply Pin<\/th>\n<td>1\/2 (+) 3\/6 (-)<\/td>\n<\/tr>\n<tr>\n<th>Max Power Per Port<\/th>\n<td>30W, IEEE 802.3 af\/at<\/td>\n<\/tr>\n<tr>\n<th>Total PWR \/ Input Voltage<\/th>\n<td>250W\/(AC100-240V)<\/td>\n<\/tr>\n<tr>\n<th>Power Consumption<\/th>\n<td>Standby&lt;15W, Full Load&lt;240W<\/td>\n<\/tr>\n<tr>\n<th>Power Supply<\/th>\n<td>Built-in power supply, AC100-240V 50-60Hz, 4.1A<\/td>\n<\/tr>\n<tr>\n<th>Operation Temp\/ Humidity<\/th>\n<td>-20~+55&#176;C, 5%~90% RH Non condensing<\/td>\n<\/tr>\n<tr>\n<th>Storage Temp\/ Humidity<\/th>\n<td>-40~+75&#176;C, 5%~95% RH Non condensing<\/td>\n<\/tr>\n<tr>\n<th>Dimension (L*W*H)<\/th>\n<td>440*290*44.5mm<\/td>\n<\/tr>\n<tr>\n<th>Net \/Gross Weight<\/th>\n<td>3.6kg\/4.5kg<\/td>\n<\/tr>\n<tr>\n<th>\u0627\u0644\u062a\u0631\u0643\u064a\u0628<\/th>\n<td>Desktop, wall mount, 1U\/19\u201d cabinet<\/td>\n<\/tr>\n<tr>\n<th>Lightning Protection<\/th>\n<td>Lightning protection: 4KV 8\/20us, Protection level: IP30<\/td>\n<\/tr>\n<tr>\n<th>Certification<\/th>\n<td>CCC, CE mark, commercial, CE\/LVD EN62368-1, FCC Part 15 Class B, RoHS<\/td>\n<\/tr>\n<tr>\n<th>Warranty<\/th>\n<td>3 years, lifelong maintenance<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<ul class=\"abm-features\">\n<li>16 \u0645\u0646\u0641\u0630 PoE \u062c\u064a\u062c\u0627\u0628\u062a \u0644\u0644\u0628\u064a\u0627\u0646\u0627\u062a \u0648\u0627\u0644\u0637\u0627\u0642\u0629<\/li>\n<li>\u0645\u0646\u0641\u0630\u0627 Uplink \u062c\u064a\u062c\u0627\u0628\u062a RJ45<\/li>\n<li>\u0645\u0646\u0641\u0630\u0627 Uplink \u0623\u0644\u064a\u0627\u0641 \u0636\u0648\u0626\u064a\u0629 SFP \u062c\u064a\u062c\u0627\u0628\u062a<\/li>\n<li>\u062a\u062d\u0633\u0633 \u062a\u0644\u0642\u0627\u0626\u064a 10\/100\/1000Base-T \u0645\u0639 \u062f\u0639\u0645 Full\/Half Duplex \u0648MDI\/MDI-X<\/li>\n<li>\u064a\u062f\u0639\u0645 \u0643\u0627\u0628\u0644\u0627\u062a UTP \u0645\u0646 Cat3 \u0625\u0644\u0649 Cat5e \u062d\u062a\u0649 100 \u0645\u062a\u0631<\/li>\n<li>\u0645\u0646\u0627\u0641\u0630 SFP \u062a\u062f\u0639\u0645 \u0627\u0644\u0623\u0644\u064a\u0627\u0641 \u0623\u062d\u0627\u062f\u064a\u0629 \u0648\u0645\u062a\u0639\u062f\u062f\u0629 \u0627\u0644\u0623\u0646\u0645\u0627\u0637 (\u0648\u062d\u062f\u0627\u062a \u0627\u062e\u062a\u064a\u0627\u0631\u064a\u0629)<\/li>\n<li>\u0645\u0633\u0627\u0641\u0629 \u0646\u0642\u0644 \u0639\u0628\u0631 \u0627\u0644\u0623\u0644\u064a\u0627\u0641 \u062d\u062a\u0649 120 \u0643\u0645 \u062d\u0633\u0628 \u0627\u0644\u0648\u062d\u062f\u0629<\/li>\n<li>\u0645\u062a\u0648\u0627\u0641\u0642 \u0645\u0639 \u0645\u0639\u0627\u064a\u064a\u0631 IEEE 802.3 \/ 802.3u \/ 802.3ab \/ 802.3z \/ 802.3x<\/li>\n<li>\u062a\u0628\u062f\u064a\u0644 \u0628\u062a\u0642\u0646\u064a\u0629 Store-and-Forward \u0628\u0623\u062f\u0627\u0621 \u0628\u0627\u0644\u0633\u0631\u0639\u0629 \u0627\u0644\u0643\u0627\u0645\u0644\u0629<\/li>\n<li>\u0633\u0639\u0629 \u062a\u0628\u062f\u064a\u0644 56 \u062c\u064a\u062c\u0627\u0628\u062a\/\u062b\u0627\u0646\u064a\u0629 \u0628\u062f\u0648\u0646 \u0627\u062e\u062a\u0646\u0627\u0642<\/li>\n<li>\u0645\u0639\u062f\u0644 \u062a\u0645\u0631\u064a\u0631 29.76 \u0645\u0644\u064a\u0648\u0646 \u062d\u0632\u0645\u0629\/\u062b\u0627\u0646\u064a\u0629 \u0644\u062d\u0632\u0645 64 \u0628\u0627\u064a\u062a<\/li>\n<li>\u062c\u062f\u0648\u0644 \u0639\u0646\u0627\u0648\u064a\u0646 MAC \u0628\u0633\u0639\u0629 8K \u0645\u0639 \u0630\u0627\u0643\u0631\u0629 \u062a\u062e\u0632\u064a\u0646 \u0645\u0624\u0642\u062a 4 \u0645\u064a\u063a\u0627\u0628\u0627\u064a\u062a<\/li>\n<li>\u064a\u062f\u0639\u0645 \u0625\u0637\u0627\u0631\u0627\u062a Jumbo \u0628\u062d\u062c\u0645 9.6K<\/li>\n<li>\u062a\u063a\u0630\u064a\u0629 PoE \u0628\u0645\u0639\u064a\u0627\u0631 IEEE 802.3af\/at \u062d\u062a\u0649 30 \u0648\u0627\u0637 \u0644\u0643\u0644 \u0645\u0646\u0641\u0630<\/li>\n<li>\u0625\u062c\u0645\u0627\u0644\u064a \u0637\u0627\u0642\u0629 PoE \u062d\u062a\u0649 250 \u0648\u0627\u0637<\/li>\n<li>\u0645\u0632\u0648\u062f \u0637\u0627\u0642\u0629 AC \u0645\u062f\u0645\u062c (100\u2013240 \u0641\u0648\u0644\u062a\u060c 50\/60 \u0647\u0631\u062a\u0632)<\/li>\n<li>\u0645\u0624\u0634\u0631\u0627\u062a LED \u0644\u062d\u0627\u0644\u0629 \u0627\u0644\u0637\u0627\u0642\u0629 \u0648\u0627\u0644\u0634\u0628\u0643\u0629 \u0648PoE \u0648\u0627\u0644\u0623\u0644\u064a\u0627\u0641<\/li>\n<li>\u0625\u0639\u0627\u062f\u0629 \u0636\u0628\u0637 \u0627\u0644\u0645\u0635\u0646\u0639 \u0628\u0632\u0631 \u0648\u0627\u062d\u062f<\/li>\n<li>\u062a\u0631\u0643\u064a\u0628 \u0645\u0643\u062a\u0628\u064a \u0623\u0648 \u062c\u062f\u0627\u0631\u064a \u0623\u0648 \u0636\u0645\u0646 \u062e\u0632\u0627\u0646\u0629 19\u2033 \u0628\u0627\u0631\u062a\u0641\u0627\u0639 1U<\/li>\n<li>\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0627\u0644\u0635\u0648\u0627\u0639\u0642 \u062d\u062a\u0649 4 \u0643\u064a\u0644\u0648\u0641\u0648\u0644\u062a \u0645\u0639 \u062f\u0631\u062c\u0629 \u062d\u0645\u0627\u064a\u0629 IP30<\/li>\n<\/ul>\n<p><a class=\"button abm-datasheet\" href=\"https:\/\/abmmaster.com\/wp-content\/uploads\/2026\/10\/PLN-1116GB-SFP-Datasheet-v2.pdf\" target=\"_blank\" rel=\"noopener\">\u062a\u062d\u0645\u064a\u0644 \u0627\u0644\u0646\u0634\u0631\u0629 \u0627\u0644\u0641\u0646\u064a\u0629 (PDF)<\/a><\/p>","protected":false},"featured_media":2727,"template":"","meta":[],"product_brand":[],"product_cat":[54],"product_tag":[49],"class_list":["post-2728","product","type-product","status-publish","has-post-thumbnail","product_cat-network-switches","product_tag-pollo","first","instock","shipping-taxable","product-type-simple","layout-style-2","col-md-4 col-sm-4 col-xs-6","col-lg-3","product-style-default"],"_links":{"self":[{"href":"https:\/\/abmmaster.com\/ar\/wp-json\/wp\/v2\/product\/2728","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/abmmaster.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/abmmaster.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/abmmaster.com\/ar\/wp-json\/wp\/v2\/media\/2727"}],"wp:attachment":[{"href":"https:\/\/abmmaster.com\/ar\/wp-json\/wp\/v2\/media?parent=2728"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/abmmaster.com\/ar\/wp-json\/wp\/v2\/product_brand?post=2728"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/abmmaster.com\/ar\/wp-json\/wp\/v2\/product_cat?post=2728"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/abmmaster.com\/ar\/wp-json\/wp\/v2\/product_tag?post=2728"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}